ILLUSTRATIVE · FICTITIOUS FIGURES · NOT A CLIENT RESULT
Fictitious laboratory: analytical testing laboratory, 22 FTE, 640 m², reporting year 2025.
01Executive decision summary
Within the declared boundary, the laboratory's operational footprint for 2025 is estimated at 95.5 tCO2e (plausible range 80.6 to 110.4), or 4.34 tCO2e per FTE, linked to €235,500 of annual operating and purchasing cost. Ventilation, fume hoods and consumables account for 59% of emissions. Five actions are estimated to save €29,600 per year and 18.6 tCO2e (20% of the baseline) for €11,400 of investment, a simple payback of about 5 months.
- 95.5 tCO2e
- ± 16 %
- 4.34 tCO2e
- Saving EUR/yr
- €29,600
02Declared boundary and data quality
Included
- Electricity for ventilation, fume hoods, cold storage and equipment
- Natural gas for space heating
- Mains and purified water
- Hazardous and general waste
- Laboratory gases
- Consumables and chemicals (spend-based)
Excluded (declared)
- Business travel and staff commuting
- Embodied emissions of capital equipment
- Cloud and IT services
- Shared building areas outside the laboratory floor
Overall data quality: carbon-weighted Grade B, uncertainty about ±16%.
03Cost and carbon hotspots
| Source | tCO2e | Share | Cost EUR/yr | Evidence |
|---|---|---|---|---|
| Ventilation and fume hoods (sub-metered electricity) | 31.2 | 33 % | €33,800 | A |
| Consumables and chemicals | 24.8 | 26 % | €148,000 | C |
| Cold storage and equipment (allocated electricity) | 18.6 | 19 % | €20,100 | B |
| Space heating (natural gas) | 14.1 | 15 % | €9,700 | B |
| Hazardous and general waste | 3.9 | 4 % | €12,400 | A |
| Laboratory gases | 2.3 | 2 % | €8,600 | C |
| Mains and purified water | 0.6 | 1 % | €2,900 | B |
| Total | 95.5 | 100 % | €235,500 | B |
04Prioritised action register
| # | Action | Saving EUR/yr | tCO2e/yr | Investment EUR | Decision owner | Evidence to confirm |
|---|---|---|---|---|---|---|
| 1 | Sash-closure routine and night setback on fume hoods | €9,500 | 8.8 | €4,000 | Lab manager + estates | Sub-meter readings before and after |
| 2 | Reusable glassware for three high-volume methods; supplier take-back | €11,000 | 3.1 | €6,500 | Procurement | Purchase records over 6 months |
| 3 | Consolidate -80 °C freezers and raise set-point to -70 °C where sample policy allows | €4,200 | 3.9 | €0 | Group leaders | Freezer inventory and power logging |
| 4 | Timed shutdown of 14 non-critical instruments | €2,600 | 2.4 | €900 | Lab manager | Timer schedule and spot metering |
| 5 | Reduce mis-sorted hazardous waste | €2,300 | 0.4 | €0 | Safety officer | Waste contractor notes |
| Total | €29,600 | 18.6 | €11,400 |
05Evidence gaps and next-step options
Evidence gaps
- Consumables are spend-based (Grade C): request supplier-specific emission data for the top 10 items.
- Gas cylinders lack supplier data (Grade C): request delivery records with gas composition.
- Cold-storage electricity is allocated (Grade B): a two-week power logging would move it to Grade A.
Next-step options
- Implement actions 1 to 3 and re-measure after one quarter.
- Track progress in the software, or repeat the Sprint next year.
- Commission an evidence review only if a tender or customer asks for documented evidence.
Figures in this sample are fictitious and are rounded. A client report uses the client's own boundary, records, evidence grades and exclusions.