// methodology traceability register
WHAT THE MODEL DOCUMENTS, AND WHAT IT DOES NOT YET CLAIM.
This register separates available evidence from work that remains incomplete. It helps laboratory leaders decide when a screening result is sufficient and when an evidence review or independent verifier is needed.
Activity-factor register
// Factor Catalogue v2.0.0
Version 2 separates documented automatic values and documented proxies from activities that require primary data or a documented custom factor. Primary-data-required activities are excluded from automatic totals rather than assigned an unsupported generic value.
Product Carbon Footprint register
// Item-level sources disclosed
The Product Carbon Footprint screen reports the climate-change indicator in kg CO2e for selected items. It is not a complete multi-impact life-cycle assessment.
Typology classification
// Numeric peer comparisons withdrawn
Labs are classified by operating typology. Numeric peer medians are not displayed until a published protocol documents source, geography, period, sample, unit, licence, and uncertainty.
Boundary, allocation, and uncertainty
// Declared per assessment
Each assessment must state its boundary, included activities, units, evidence grade, inputs, exclusions, and limitations. Shared-consumption allocation must be documented explicitly.
Methodology changes and corrections
// Signed record controls
Signed assessment records identify their method version and registry status. Material changes should lead to correction, supersession, or withdrawal as appropriate.
// factor values
ACTIVITY-FACTOR REGISTER
Current built-in representative factors are shown with explicit disclosure gaps; absent sources, geography, and data years are not inferred.
| Activity | Category | Unit | kg CO2e / unit | Applicability | Derivation status | Bibliographic source status |
|---|---|---|---|---|---|---|
| Fume hood (VAV) | Energy | hoods | — | Chemistry, Biology, Materials science, Environmental science | Primary data required A universal per-hood default is not defensible. Provide annual metered or manufacturer-estimated kWh and a documented electricity factor. | Primary data required A universal per-hood default is not defensible. Provide annual metered or manufacturer-estimated kWh and a documented electricity factor. |
| Fume hood (CAV) | Energy | hoods | — | Chemistry, Biology, Materials science, Environmental science | Primary data required A universal per-hood default is not defensible. Provide annual metered or manufacturer-estimated kWh and a documented electricity factor. | Primary data required A universal per-hood default is not defensible. Provide annual metered or manufacturer-estimated kWh and a documented electricity factor. |
| ULT freezer (-80°C) | Energy | freezers | 1511.465 | Biology, Chemistry, Environmental science | Documented sourced proxy 20 kWh/day × 365 days × 0.20705 kg CO2e/kWh (DESNZ 2024 UK electricity) = 1,511.47 kg CO2e/freezer-year. | Purchasing Energy-Efficient Laboratory Grade Refrigerators and Freezers U.S. Department of Energy, Federal Energy Management Program · 2023 · United States conventional laboratory freezer market; proxy outside the U.S. Use-phase electricity demand only; electricity emissions are calculated with the documented DESNZ 2024 UK grid factor. |
| Standard freezer (-20°C) | Energy | freezers | — | all | Primary data required Collect annual electricity consumption from an ENERGY STAR record, meter, or manufacturer specification; no universal -20°C default is applied. | Primary data required Collect annual electricity consumption from an ENERGY STAR record, meter, or manufacturer specification; no universal -20°C default is applied. |
| Steam autoclave | Energy | autoclaves | — | Biology, Environmental science, Civil engineering | Primary data required Autoclave energy and water use depend on cycle load, standby mode, steam source, and cooling configuration; provide primary cycle and utility data. | Primary data required Autoclave energy and water use depend on cycle load, standby mode, steam source, and cooling configuration; provide primary cycle and utility data. |
| General laboratory HVAC | Energy | m2 | — | all | Primary data required Heating, cooling, and ventilation require metered energy or a building allocation with declared climate, fuel, and air-change assumptions. | Primary data required Heating, cooling, and ventilation require metered energy or a building allocation with declared climate, fuel, and air-change assumptions. |
| Laboratory lighting (LED) | Energy | m2 | — | all | Primary data required Collect installed lighting wattage and annual operating hours; an office-based lighting-density proxy is not used as an automatic laboratory default. | Primary data required Collect installed lighting wattage and annual operating hours; an office-based lighting-density proxy is not used as an automatic laboratory default. |
| Laboratory lighting (fluorescent) | Energy | m2 | — | all | Primary data required Collect fixture wattage and annual operating hours; the LED proxy is not applied to fluorescent systems. | Primary data required Collect fixture wattage and annual operating hours; the LED proxy is not applied to fluorescent systems. |
| RO/DI water system | Water | L_produced | — | Biology, Chemistry, Materials science, Environmental science, Electronics | Primary data required RO/DI impacts depend on recovery rate, electricity use, resin regeneration, and local water treatment. Enter a documented custom factor or primary utility data. | Primary data required RO/DI impacts depend on recovery rate, electricity use, resin regeneration, and local water treatment. Enter a documented custom factor or primary utility data. |
| Single-pass cooling water | Water | m³ water | 0.33885 | Chemistry, Physics, Materials science | Documented sourced default 0.15311 kg CO2e/m³ water supply + 0.18574 kg CO2e/m³ water treatment = 0.33885 kg CO2e/m³. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation Scope 3 water supply and treatment. Does not include site-specific pumping or chiller electricity. |
| Biohazardous waste | Waste | kg | — | Biology, Environmental science | Primary data required Select and document the actual treatment route, transport, waste composition, and energy-recovery status; no generic clinical-waste default is applied. | Primary data required Select and document the actual treatment route, transport, waste composition, and energy-recovery status; no generic clinical-waste default is applied. |
| Chemical waste (solvents) | Waste | L | — | Chemistry, Materials science, Environmental science | Primary data required Solvent waste requires solvent identity, density, and actual treatment route; no generic per-litre factor is applied. | Primary data required Solvent waste requires solvent identity, density, and actual treatment route; no generic per-litre factor is applied. |
| Electronic waste | Waste | kg | — | all | Primary data required Electronic-waste impacts depend on product mix, reuse/recycling route, and system boundary; provide a documented recycler or product-specific record. | Primary data required Electronic-waste impacts depend on product mix, reuse/recycling route, and system boundary; provide a documented recycler or product-specific record. |
| Purchased organic solvents | Chemicals | L | — | Chemistry, Materials science, Environmental science | Primary data required Use solvent-specific product footprints or a documented spend-based chemical factor. A generic mixed-solvent factor is not applied. | Primary data required Use solvent-specific product footprints or a documented spend-based chemical factor. A generic mixed-solvent factor is not applied. |
| HPC compute node | Computing | nodes | — | Server room, Physics, Biology, Chemistry | Primary data required Separate metered use-phase kWh from model-specific embodied emissions; a generic node count is not a defensible activity basis. | Primary data required Separate metered use-phase kWh from model-specific embodied emissions; a generic node count is not a defensible activity basis. |
| High-end workstation | Computing | workstations | — | all | Primary data required Use metered or manufacturer-reported annual kWh and, where material, a product-specific PCF. A generic workstation count is not a defensible activity basis. | Primary data required Use metered or manufacturer-reported annual kWh and, where material, a product-specific PCF. A generic workstation count is not a defensible activity basis. |
| Short-haul flights | Transport | flights | 557.76 | all | Documented sourced proxy 2 × 1,500 passenger-km default distance × 0.18592 kg CO2e/passenger-km = 557.76 kg CO2e/return flight. The 1,500 km distance is a disclosed GreenLabCalc proxy, not a DESNZ route definition. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation DESNZ Scope 3 business travel, short-haul average passenger, to/from UK. Cabin class and actual route distance can materially change results. |
| Long-haul flights | Transport | flights | 3135.36 | all | Documented sourced proxy 2 × 6,000 passenger-km default distance × 0.26128 kg CO2e/passenger-km = 3,135.36 kg CO2e/return flight. The 6,000 km distance is a disclosed GreenLabCalc proxy, not a DESNZ route definition. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation DESNZ Scope 3 business travel, long-haul average passenger, to/from UK. Cabin class and actual route distance can materially change results. |
| Cold-chain shipping | Transport | shipments | — | Biology, Chemistry, Environmental science | Primary data required Cold-chain shipment impacts require mass, mode, distance, container type, refrigerant or dry-ice use, and storage time. | Primary data required Cold-chain shipment impacts require mass, mode, distance, container type, refrigerant or dry-ice use, and storage time. |
| Single-use plastics | Consumables | kg | 3.16478 | Biology, Chemistry, Environmental science | Documented sourced default DESNZ 2024 material-use record: 3,164.78 kg CO2e/tonne ÷ 1,000 = 3.16478 kg CO2e/kg. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation Scope 3 material use. Product-specific forming, sterilisation, packaging, transport, and end-of-life are excluded. |
| Nitrile/latex gloves | Consumables | boxes | — | all | Primary data required Disposable-glove impacts require material, mass per glove, supplier/manufacturing data, and disposal route. A universal box factor is not applied. | Primary data required Disposable-glove impacts require material, mass per glove, supplier/manufacturing data, and disposal route. A universal box factor is not applied. |
| Liquid nitrogen (LN2) | Gases | L | — | Biology, Physics, Materials science, Chemistry | Primary data required Use a supplier PCF or documented liquefaction energy with a declared electricity factor. A generic litre factor is not applied. | Primary data required Use a supplier PCF or documented liquefaction energy with a declared electricity factor. A generic litre factor is not applied. |
| Liquid helium | Gases | L | — | Chemistry, Physics, Materials science | Primary data required Use a supplier PCF or documented recovery/liquefaction data. A generic litre factor is not applied. | Primary data required Use a supplier PCF or documented recovery/liquefaction data. A generic litre factor is not applied. |
| New major equipment | Equipment | items | — | all | Primary data required Use model-specific product footprint or a documented spend-based source with fixed currency year and commodity classification. | Primary data required Use model-specific product footprint or a documented spend-based source with fixed currency year and commodity classification. |
| Heating/cooling allocation | Energy | MWh district heat | 179.65 | all | Documented sourced default 0.17965 kg CO2e/kWh × 1,000 kWh/MWh = 179.65 kg CO2e/MWh. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation DESNZ Scope 2 district heat and steam only. Cooling, gas boilers, heat pumps, and other thermal sources are excluded. |
| Hazardous waste disposal | Waste | kg | — | Chemistry, Biology, Materials science, Environmental science, Corporate R&D | Primary data required Hazardous waste requires the actual waste class, treatment route, transport, and energy-recovery status; no generic disposal factor is applied. | Primary data required Hazardous waste requires the actual waste class, treatment route, transport, and energy-recovery status; no generic disposal factor is applied. |
| Procurement (Scope 3 spend-based) | Equipment | kEUR spend | — | all | Primary data required Use an explicit commodity-specific EEIO factor in the source currency year or supplier product footprints; a generic EUR-spend factor is not applied. | Primary data required Use an explicit commodity-specific EEIO factor in the source currency year or supplier product footprints; a generic EUR-spend factor is not applied. |
| Office workstations | Computing | workstations | — | SME office, Corporate R&D | Primary data required Use metered annual kWh or product-specific PCFs; a generic count of office workstations is not a defensible activity basis. | Primary data required Use metered annual kWh or product-specific PCFs; a generic count of office workstations is not a defensible activity basis. |
| Office HVAC (per 100 m²) | Energy | 100 m² units | — | SME office, Corporate R&D, Manufacturing | Primary data required Use metered heating and cooling data or a disclosed building allocation; area-only defaults are not applied. | Primary data required Use metered heating and cooling data or a disclosed building allocation; area-only defaults are not applied. |
| Business air travel | Transport | flights | — | SME office, Corporate R&D, Manufacturing | Primary data required Use passenger-km by mode and route, then select a documented mode-specific factor. A generic flight count is not applied. | Primary data required Use passenger-km by mode and route, then select a documented mode-specific factor. A generic flight count is not applied. |
| Employee commuting (car) | Transport | employees | — | SME office, Corporate R&D, Manufacturing | Primary data required Use passenger-km by mode and reported occupancy; employees counted as car commuters are not a defensible activity basis. | Primary data required Use passenger-km by mode and reported occupancy; employees counted as car commuters are not a defensible activity basis. |
| Office printing | Consumables | kg paper | 1.33932 | SME office, Corporate R&D | Documented sourced default DESNZ 2024 paper material-use record: 1,339.32 kg CO2e/tonne ÷ 1,000 = 1.33932 kg CO2e/kg. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation Scope 3 paper material use. Printing electricity, toner, and end-of-life are excluded. |
| Compressed air system | Energy | kW compressors | — | Manufacturing, Corporate R&D | Primary data required Use metered compressor kWh and a documented electricity factor; installed compressor capacity alone is not a defensible activity basis. | Primary data required Use metered compressor kWh and a documented electricity factor; installed compressor capacity alone is not a defensible activity basis. |
| Process / production water | Water | m³ | 0.33885 | Manufacturing, Corporate R&D | Documented sourced default 0.15311 kg CO2e/m³ water supply + 0.18574 kg CO2e/m³ water treatment = 0.33885 kg CO2e/m³. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation Scope 3 water supply and treatment. Site-specific process pumping, heating, or cooling is excluded. |
| Product packaging | Consumables | tonnes paperboard | 1193.97 | Manufacturing | Documented sourced default DESNZ 2024 paper-and-board record: 1,193.97 kg CO2e/tonne. | Greenhouse gas reporting: conversion factors 2024 UK Department for Energy Security and Net Zero · 2024 · United Kingdom; use outside the UK requires an explicit geography limitation Scope 3 material use. This record applies to paperboard only, not mixed paper-and-plastic packaging. |
| Outbound freight (road) | Transport | 1000 tkm | — | Manufacturing | Primary data required Use actual tonne-km or vehicle-km, vehicle class, load factor, and route. The current generic thousand-tonne-km factor is withdrawn. | Primary data required Use actual tonne-km or vehicle-km, vehicle class, load factor, and route. The current generic thousand-tonne-km factor is withdrawn. |
// product footprint sources
ITEM-LEVEL SOURCE REGISTER
| Item | Category | Functional unit | Reusable | Typical uses | Source note |
|---|---|---|---|---|---|
| Polypropylene pipette tips | Consumables | kg | No | 1 | PlasticsEurope Eco-profiles; PLOS Sustainability 2023 |
| Polystyrene Petri dishes | Consumables | kg | No | 1 | Ecoinvent 3.8 |
| Nitrile gloves | Consumables | kg | No | 1 | UCL LEAF data; NHS England Carbon Footprint |
| Reusable glass pipette | glassware | kg | Yes | 100 | PLOS One 2023: Re-use of laboratory utensils reduces CO2 footprint |
| Reusable glass Petri dish | glassware | kg | Yes | 50 | PLOS One 2023 |
| Acetonitrile | solvents | liter | No | 1 | ACS Sustainable Chem. Eng. 2024; Springer Anal Bioanal Chem 2026 |
| Methanol | solvents | liter | No | 1 | ACS Sustainable Chem. Eng. 2024 |
| Bio-based ethanol | solvents | liter | No | 1 | RSC Green Chemistry |
| Acetone | solvents | liter | No | 1 | Ecoinvent 3.8 |
| ULT freezer | Equipment | unit | Yes | 10 | My Green Lab / ACT Label Database averages |
// typology classification
NUMERIC COMPARISON STATUS
| Typology | Reference status | Population | Period | Geography | Use limitation |
|---|---|---|---|---|---|
| Wet chemistry | Numeric reference withdrawn | Not published | Not published | Not published | Do not use typology classification as a public rank, tender score, or performance-verification basis. |
| Life sciences | Numeric reference withdrawn | Not published | Not published | Not published | Do not use typology classification as a public rank, tender score, or performance-verification basis. |
| Physical & Engineering | Numeric reference withdrawn | Not published | Not published | Not published | Do not use typology classification as a public rank, tender score, or performance-verification basis. |
| Computational / dry laboratory | Numeric reference withdrawn | Not published | Not published | Not published | Do not use typology classification as a public rank, tender score, or performance-verification basis. |
| Shared / General Purpose | Numeric reference withdrawn | Not published | Not published | Not published | Do not use typology classification as a public rank, tender score, or performance-verification basis. |
| Corporate / SME Facility | Numeric reference withdrawn | Not published | Not published | Not published | Do not use typology classification as a public rank, tender score, or performance-verification basis. |
DECISION-READINESS METHOD
How the platform chooses a defensible pathway
GreenLabCalc evaluates organisational context, data access and decision authority before calculating. When the evidence cannot support a complete footprint, it routes the user to a bounded estimate, maturity diagnostic or review of an existing footprint.
Eligibility routing
Context, intended output, prior footprint, core data domains and shared-data participation determine the recommended pathway.
Four data classes
Direct, documented allocation, screening estimate and unavailable are kept separate. An unavailable input is never silently converted into zero emissions.
Interpretable confidence
Completeness, unit specificity, recency and provenance are shown separately. This is decision-support confidence, not statistical assurance.
Control ownership
Actions and data requests identify the laboratory, department, institution, supplier or landlord able to provide evidence or authorize change.
Existing-footprint review
Manual report metadata and category totals retain their original methodology. GreenLabCalc does not claim automatic GES 1point5 interoperability or recalculation.
Comparison safeguard
Public numeric peer ranking remains withdrawn. Any future comparison requires an opt-in, quality-screened and context-matched cohort protocol.
// boundary and allocation
DECLARED-BOUNDARY REGISTER
| Topic | Current rule | Disclosure required |
|---|---|---|
| Organisational boundary | Declared by the assessment user. | A whole-organisation inventory is not assumed. |
| Included activities | Only selected activities with entered quantities are calculated. | Unselected activities must be disclosed. |
| Allocation approach | Allocation basis is not inferred automatically. | Document metering, floor area, hours, headcount, or another justified key. |
| Operational scope | Relevant activities are calculated only when in scope. | No universal completeness claim is made. |
| Uncertainty treatment | Evidence grades produce a screening uncertainty indication. | This is not a formal uncertainty study. |
// exclusions
EXCLUSIONS REGISTER
| Exclusion | Current handling | Reporting impact |
|---|---|---|
| Activities not selected | Excluded from totals. | State that totals cover selected activities and declared boundary only. |
| Missing operational records | No automatic imputation beyond configured factors and entered quantities. | Disclose missing records, estimates, and generic assumptions. |
| Non-climate impact categories | Climate-change indicator only in kg CO2e. | Do not present as a complete multi-impact LCA. |
| Automatic shared-use allocation | No automatic allocation key. | Document justified allocation before Grade B use. |
| External compliance or assurance | Decision-support output only. | Not automatically verified, accredited, certified, compliant, or sufficient for every external purpose. |
Evidence and uncertainty grades
Primary invoices, metering, or procurement records linked to the assessed activity.
A documented departmental allocation using a stated and reviewable allocation key.
Estimated activity data using a declared operational assumption.
A generic configured assumption used only for screening.
Methodology-change log
Pre-register history · Disclosure gap · Historic effective dates are unavailable
A formal historic version record was not maintained before this register.
Signed assessment records identify their method version and registry status. Material changes should lead to correction, supersession, or withdrawal as appropriate.
GreenLabCalc Assessment Protocol v1.1 (2026-08-26) · Current · Current protocol disclosure
Current protocol disclosures were added on 2026-08-25.
Signed assessment records identify their method version and registry status. Material changes should lead to correction, supersession, or withdrawal as appropriate.
2.0.0 · Current · Current protocol disclosure
Current protocol disclosures were added on 2026-08-25.
Signed assessment records identify their method version and registry status. Material changes should lead to correction, supersession, or withdrawal as appropriate.